SPECIFICATIONS | |||
MODEL | 7305 | ||
GROUND BOND | |||
Output AC Current | 3 - 30A | ||
Output AC Voltage | 6V, Maximum | ||
Output Frequency | 50Hz/60Hz ±100ppm, User Selection | ||
SETTINGS | |||
Max-Limit | Resistance | 0-510mΩ | 0-120mΩ |
Range | AC Current | 3.0-10.0A | 10.1-30.0A |
Resolution | 1mΩ | ||
Accuracy | Same as Resistance Measurement Accuracy | ||
Min-Limit | Resistance | - | |
Range | AC Current | - | |
Resolution | 1mΩ | ||
Accuracy | Same as Resistance Measurement Accuracy | ||
Lead Resistance Offset | Range | 0 - 100 mΩ, Auto/manual | |
Resolution | 1mΩ | ||
Accuracy | ±(2% of setting +2 counts) | ||
Dwell Time | Range | 0, 0.5 - 999.9 sec (0 = continuous) | |
Resolution | 0.1 sec | ||
Accuracy | ±(0.1% + 0.05sec) | ||
MEASUREMENT | |||
AC Current | Range | 3.0 - 30.0A | |
Resolution | 0.1A | ||
Accuracy | ±(2%of reading +1count) | ||
Resistance | Range | 0-510mΩ | 0-120mΩ |
3.0-10.0A | 10.1-30.0A | ||
Resolution | 1 mΩ | ||
Accuracy | ±(2%of reading +1count) | ||
GENERAL | |||
Input Voltage AC | 115/230Vac±15%, 50/60Hz ± 5%, Fuse 6.3A for 7305/7315 model, 10A for 7314 model, 15A for 7316 model | ||
PLC Remote Control | Input: Test , Reset,Withstand Processing ,(Memory1.2.3, Interlock for 7314/7315/7316 model only) | ||
| Output: Pass , Fail , Processing , Reset Out , Start Out
| ||
Memory | 5 memories | ||
Display | 16×2 LCD with back light | ||
Key Lock | To prevent unauthorized alteration of the test Parameters | ||
Calibration | Build-in software and external calibrated meters | ||
Verification | - | ||
Alarm Volume Setting | - | ||
Environment | 0-40℃, 20-80%RH | ||
Dimension | 280(W)×89(H)×370(D)mm | ||
Net Weight | 10Kg | ||
STANDARD ACCESSORIES | |||
Power Cord(10A) | ×1 | ||
Fuses | ×2 (Including a spare contained in the fuse holder) | ||
Ground Bond Return Lead 30A ,1.6m(1122) | ×1 | ||
Ground Bond Test Lead 30A,1.6m(1131) | ×1 |