智能毫安回路校验仪UPS II | 过程校验仪MVX | 多功能校验仪VAX II | 多功能过程校验仪DPI 720 |
●测量/输出0-21mA | ●测量/输出mV和mA | ●产生脉冲/测量频率 | ●模拟/测量电阻和热电偶 |
便携式多功能校验仪TRX | 多功能过程校验仪TRX II | 多功能过程校验仪MCX II |
●模拟/测量热电阻和热电偶 | ●模拟/测量热电阻和热电偶 | ●模拟/测量热电阻和热电偶 |
型号 | MVX | VAXII | DPI720 | TRX | TRXII | MCXII |
mA | 52mA/0.04% | 52mA/0.05% | 21mA/0.04% | 52mA/0.05% | 52mA/0.01% | 52mA/0.01% |
mV | 120mV/0.017% | 120mV/0.025% | 210mV/0.04% | 120mV/0.025% | 600mV/0.025% | 600mV/0.005% |
V | 120V/0.04% | 120V/0.05% | 21V/0.04% | 120V/0.05% | 60V/0.05% | 60V/0.009% |
欧姆 | 3000Ω/0.04% | 390Ω/0.1Ω | 2000Ω/0.02% | 2000Ω/0.01% | ||
热电偶 | -250/1370℃/1℃ | -230/1370℃ /0.6℃ | -250/1370℃ /0.6℃ | -250/1370℃/1℃ | ||
热电阻 | -200/850℃/0.6℃ | -200/850℃ /0.25℃ | -200/850℃ /0.25℃ | -200/850℃/0.15℃ | ||
频率 | 10,000Hz/1Hz | 20,000Hz/1Hz | 10,000Hz/1Hz | |||
脉冲计数 | 0-107-1 | 0~108-1/1p/min | 0~108-1/1p/min |
型号 | MVX | VAX II | DPI 720 | TRX | TRX II | MCX II |
mA | 24mA/0.04% | 24mA/0.05% | 21mA/0.04% | 24mA/0.05% | 24mA/0.01% | 24mA/0.012% |
模拟变送器 | 24mA/0.04% | 24mA/0.05% | 21mA/0.04% | 24mA/0.05% | 24mA/0.01% | 24mA/0.012% |
mV | 120mV/0.017% | 120mV/0.025% | 210mV/0.04% | 120mV/0.025% | 100mV/0.01% | 100mV/0.003% |
V | 12V/0.017% | 12V/0.05% | 10.5V/0.04% | 12V/0.025% | 12V/0.01% | 12V/0.004% |
欧姆 | 3000Ω/0.04% | 390Ω/0.1Ω | 2000Ω/0.02% | 2000Ω/0.01% | ||
热电偶 | -250/1370℃ /1℃ | -230/1370℃ /0.3℃ | -250/1370℃ /0.3℃ | -250/1370℃ /0.1℃ | ||
热电阻 | -200/850℃ /0.6℃ | -200/850℃ /0.25℃ | -200/850℃ /0.25℃ | -200/850℃ /0.12℃ | ||
频率 | 10,000Hz/1Hz | 20,000Hz/1Hz | 10,000Hz/1Hz | |||
脉冲计数 | 0-107-1 | 0~108-1/1p/min | 0~108-1/1p/min |
注:1、量程范围/量程精度,更详细的数据请参阅相关样本;
2、IS本安型的电流输出为21mA
3、DPI 720是新推出的产品,可测量/输出的热电偶为K,J,L,T,U,B,R,S,E,N共10种,热电阻为
Pt100,Ni100两种;
4、TRX II和MCX II可测量/输出的热电偶为K,J,L,T,U,B,R,S,E,N,C,D共12种,此处仅标出
K型的范围的精度,且此精度不包括冷端补偿的误差±0.2℃,其他精度请参阅相关样本;
5、TRX II和MCX II可测量/输出的热电阻为Pt1000,Pt500,Pt200,Pt100,Pt50,D100,Ni120,Cu10共9种,此处仅
标出Pt100的范围和精度,其他精度请参阅相关样本;
TRX II和MCX II的外部压力传感器压力量程范围
型号 | TRX II | MCX II | ||||||
量程 | 精度 | 表压 | 绝压 | 量程 | 精度 | 表压 | 绝压 | |
压力范围 | 0-7kPa | 0.1%FS | #800 | -100-0kPa | 0.1%FS | #612 | ||
0-20kPa | 0.05%FS | #802 | 0-35kPa | ±1Pa | #611 | #611A | ||
0-35kPa | 0.05%FS | #803 | #853 | 0-140kPa | 0.05%rdg+0.01%FS | #610 | #610A | |
-70-70kPa | 0.05%FS | #804 | #854 | 0-200kPa | 0.05%rdg+0.01%FS | #601 | #601A | |
-100-100kPa | 0.05%FS | #805 | #855 | 0-350kPa | 0.05%rdg+0.01%FS | #620 | #620A | |
-100-200kPa | 0.05%FS | #807 | #857 | 0-700kPa | 0.05%rdg+0.01%FS | #602 | #602A | |
-100-400kPa | 0.05%FS | #809 | #859 | 0-1MPa | 0.05%rdg+0.01%FS | #603 | #603A | |
-100-700kPa | 0.05%FS | #811 | #862 | 0-1.4MPa | 0.05%rdg+0.01%FS | #621 | #621A | |
-0.1-2MPa | 0.05%FS | #814 | #864 | 0-2MPa | 0.05%rdg+0.01%FS | #607 | #607A | |
-0.1-3.5MPa | 0.05%FS | #816 | #866 | 0-4MPa | 0.05%rdg+0.01%FS | #604 | #604A | |
0-4MPa | 0.05%FS | #817 | #867 | 0-7MPa | 0.05%rdg+0.01%FS | #605 | #605A | |
0-7MPa | 0.05%FS | #818 | #868 | 0-12MPa | 0.05%rdg+0.01%FS | #606 | ||
0-20MPa | 0.05%FS | #822 | 0-13.5MPa | 0.05%rdg+0.01%FS | #623 | |||
0-40MPa | 0.05%FS | #824 | 0-20MPa | 0.05%rdg+0.01%FS | #624 | |||
0-70MPa | 0.05%FS | #826 | 0-35 | 0.05%rdg+0.01%FS | #625 |
注:1、TRX II的压力接口为G1/4内螺纹,并可提供G1/4和1/4NPT外螺纹的转换接头,用一根1.5m长的PTFE匹配电
缆连接到TRX II上;
2、以上仅列出一部分的传感器量程,更多的量程请参阅相关样本;
3、MCX II的外部压力传感器有两个压力接口(即可实现两个量程的校验),选型时应注明压力量程和相应的压力
接口;
配套软件
型号 | Linkpak-W校验软件 | Intecal-W校验数据库软件 |
适合于工业过 程的厂区、车 间、系统项目、 生产厂家和专 业服务公司, 提高校验过程 和文件制作的 效率 | ||
功能 | 软件有助于用户为满足工业质量管理体系 的需要和校验文件制作。测试程序的设计 基于Windows应用场合,可以报告测试结 果,也可组合为现场使用的工作指令。测 试结果可上载到计算机用于数据分析和校 验证书的打印。 | 在Linkpak-W基础上发展的数据库软件,可支 持便携式现场校验仪和实验室校验仪,软件允 许手动输入数据,现场被校仪表的信息、校验 步聚和结果均可保存在校验仪的数据库中,还 可以根据用户定义的编号或区域增建数据库, 具有增强性的管理特性,包括数据搜索、校验 周期的提醒和标准报告打印,具有四级安全密 码系统,防止非法进入软件。 |
支持设备 | DPI 605/610,TRX II,MCX II | DPI605/610/615,TRX II, MCX II, DPI510/515/520,DPI145,Ruska7215 |