品牌
代理商厂商性质
上海市所在地
室内污染监测用微量气体采样器S-21
目前的甲醛的浓度测定方法一般是采用吸光光度法或是HPLC法。但这需要昂贵的仪器、相应的知识和熟练的操作。而简易测定法却无法测定室内微量的甲醛含量。新开发的检知管,已经能够测定0.01~1.2ppm的浓度范围,*WHO提出的室内环境*值0.1mg/m3(0.08ppm30min平均)。
Model Number | Air sampler S-21 |
Sampling pump | diaphram |
Maximum suction pressure | more than 400hPa (At full load) |
Flow rate settings range | 50 - 500mL/min |
Flow Meter Accuracy | ±5% of full scale |
Repeatability of Flow Meter | ±1% of indicated value |
Timer function | 1min?99hrs.59min. with Digital setting (addition display) *It is set to stop after 30 minutes with the shipment settings display; subtraction display |
Operating temperature range | orange to red-purple |
Power source | 0 - 40℃ |
Dimensions | 125(W) x 146(H) x 220(D)mm |
Weight | 2.5kg |
Option | Position pole to keep measuring height, Tip cutter : B191 and Thermometer |
室内空气质量监测用有毒气体快速检测管 Detector tubes for Air samplers
Application | Gas to be measured | Tube No. | (*) | Measuring range |
Indoor air pollutants | Formaldehyde | 710 Formaldehyde | 20 | 0.01-0.48ppm |
Formaldehyde | 710A Formaldehyde | 20 | 0.05-2.0ppm | |
Formaldehyde | 713 Formaldehyde | 20 | 0.01-0.50ppm | |
Toluene | 721 Toluene | 10 | 0.05-1.0ppm | |
Xylene | 721 Toluene (+) | 10 | 0.1-1.4ppm | |
Ethyl benzene | 721 Toluene (+) | 10 | 0.05-1.0ppm | |
p-Dichlorobenzene | 730 p-Dichlorobenzene | 10 | 0.01-0.40ppm | |
Nitrogen dioxide | 740 Nitrogen dioxide | 10 | 0.01-0.20ppm | |
Trichloroethylene | 750 Trichloroethylene | 10 | 30-920µg/m3 | |
Tetrachloroethylene | 760 Tetrachloroethylene | 10 | 30-920µg/m3 | |
For museums | Ammonia | 900NHH Ammonia | 10 | 10-80µg/m3 |
For clean room monitoring | Ammonia | 901NHL Ammonia | 10 | 1-12µg/m3 |
(*) shows a number of measurements per box
■ 甲醛检知管 710
使用采取器 AIR SAMPLER S-21
测定范围 0.01~1.2ppm
试料采取量 2L、3L、9L
测定时间 10分、30分
吸引流量 200ml/min、300ml/min
吸引压力 150hPa以上
颜色的变化 黄色→桃色
使用温度范围 10~35℃
使用湿度范围 15~95%RH
Currently, measurements for concentration of formaldehyde is done most commonly by absorptiometric method or HPLC (high performance liquid chromatography) method.
However, these methods require expensive devices, knowledge and experience.
Furthermore, in detector tube method which is effective as a simple measurement, up to this date it had been impossible to detect and measure the trace amount of formaldehyde at the indoor pollution level.
With Air sampler S-21, this newly developed detector tube is capable of measuring within the range of 0.01 - 1.2ppm. And it covers the indoor environment suggested value by WHO, which is 0.1mg/m3 (0.08ppm 30min average).
目前,甲醛浓度的测量,是zui常用的工作方法或absorptiometric高效液相色谱(高效液相色谱)方法。
但是,这些方法需要昂贵的设备,知识和经验。
此外,检测管法是一种简单有效的测量,到这一天,未能探测和跟踪测量的室内甲醛污染程度的数额。
与空气采样器的S - 21,这个新开发的探测器能够管内的范围0.01 - 1.2ppm测量。它涵盖了室内环境建议值由世卫组织,这是0.1mg/m3(0.08ppm 30分钟平均)。