品牌
代理商厂商性质
广州市所在地
011-0049-02 50欧姆端子美国泰克Tektronix
面议013-0309-00抓斗IC夹子美国泰克Tektronix
面议TP175-FL测试线美国泰克Tektronix
面议AC283-FL钳夹鳄鱼夹美国泰克Tektronix
面议P7516差分探头美国泰克Tektronix
面议P7350差分探头美国泰克Tektronix
面议P7330差分探头高频探头美国泰克Tektronix
面议P6249示波器探头美国泰克Tektronix
面议TDP3500 3.5G差分探头美国泰克Tektronix
面议THP0301示波器电压探头电流探头美国泰克Tektronix
面议A605电流探头美国泰克Tektronix
面议TPP1000无源电压探头电流探头美国泰克Tektronix
面议TPA-N-PRE转接头美国泰克Tektronix
购买须知:
1.请您先确定产品的具体型号。
2.如果不确定型号,可以参考我们页面上提供的详细介绍或者直接咨询我们。
3.网页上的价格仅作参考,准确价格请电联我司。
4.货期方面请与我司,因为不同产品的货期是不一样的。
5.同一产品不同时间的价格与货期也是不一样的
6.其他的具体相关事宜,请。
7.谢谢您的光临!
Features and Benefits
9 kHz - 6 GHz frequency range
12 dB gain (nominal)
10 dB DANL improvement
Applications
Measurement of low-power signals
TPA-N-PRE Preamplifier
The TPA-N-PRE preamplifier accessory for the MDO4000 and MDO3000 Series Mixed Domain Oscilloscopes provides 12 dB nominal gain, further lowering the already low noise floor in the MDO4000 and MDO3000 Series. This allows you to pull very small signals out of the noise in low-amplitude signal applications. For example, in the following screenshot we are measuring a noise floor of -114 dBm (-154 dBm/Hz) without the TPA-N-PRE preamplifier. It appears that there is only noise present.
In the screenshot below, we’ve turned on the preamplifier. Notice that the noise floor has dropped to -124 dBm (-164 dBm/Hz). As a result of the noise floor dropping significantly, we’re now able to see a -116 dBm signal present at 900 MHz that was hidden in the noise without the preamplifier.
Specifications
General
Specification | Description |
---|---|
Frequency range | Preamp alone: 9 kHz to 6 GHz Preamp and MDO: Frequency range specified by the MDO's frequency range |
Preamp gain | Amplifying state: +12 dB (nominal) Bypass state: -1.5 dB (nominal) |
Displayed average noise level (DANL) with the preamp attached to the MDO RF input | With the preamp mode set to “Auto” and the reference level set to -40 dBm (MDO4000 Series) or -30 dBm (MDO3000 Series): MDO4000C with SA6 option: 9 kHz to 50 kHz: < -119 dBm/Hz (-123 dBm/Hz typical) 50 kHz to 5 MHz: < -140 dBm/Hz (-144 dBm/Hz typical) 5 MHz to 400 MHz: < -156 dBm/Hz (-158 dBm/Hz typical) 400 MHz to 3 GHz: < -157 dBm/Hz (-159 dBm/Hz typical) 3 GHz to 4 GHz: < -158 dBm/Hz (-162 dBm/Hz typical) 4 GHz to 6 GHz: < -150 dBm/Hz (-154 dBm/Hz typical) MDO4000C with SA3 option: 9 kHz to 50 kHz: < -119 dBm/Hz (-123 dBm/Hz typical) 50 kHz to 5 MHz: < -140 dBm/Hz (-144 dBm/Hz typical) 5 MHz to 400 MHz: < -156 dBm/Hz (-158 dBm/Hz typical) 400 MHz to 3 GHz: < -157 dBm/Hz (-159 dBm/Hz typical) MDO3000 with MDO3SA option: 9 kHz to 50 kHz: < -117 dBm/Hz (-121 dBm/Hz typical) 50 kHz to 5 MHz: < -138 dBm/Hz (-142 dBm/Hz typical) 5 MHz to 2 GHz: < -148 dBm/Hz (-152 dBm/Hz typical) 2 GHz to 3 GHz: < -138 dBm/Hz (-142 dBm/Hz typical) |
Level measurement uncertainty with the preamp attached to the MDO RF input | Preamp mode set to “Auto”. Reference Level 10 dBm to –40 dBm. Input level ranging from reference level to 30 dB below reference level. Specifications exclude mismatch error. < ±1.5 dB typical, 18-28?C temperature range, either preamp state. < ±2.3 dB typical, over full operating range (temperature and humidity), either preamp state. |
Maximum operating input level with preamp attached to the MDO RF input | Average continuous power: +30 dBm (1 W) (MDO4000 Series), +20 dBm (100 mW) (MDO3000 Series) DC maximum before damage: ±20 V DC Maximum power before damage (CW): +30 dBm (1 W) Maximum power before damage (pulse): +45 dBm (32 W) (<10 μs pulse width, <1% duty cycle, and reference level of ≥ +10 dBm) |
Reference level range with preamp attached to MDO RF input | Amplifying state: -30 dBm to DANL (MDO4000 Series), -20 dBm to DANL (MDO3000 Series) Bypass state: +30 dBm to DANL (MDO4000 Series), +20 dBm to DANL (MDO3000 Series) |
Connector type | SMA – female (outside threads) |
Environmental
TPA-N-PRE转接头美国泰克Tektronix
Specification | Description |
---|---|
Temperature | |
Operating | 0 °C to +50 °C |
Nonoperating | -20 °C to +60 °C |
Humidity | |
Operating | High: 40 °C to 50 °C (104 °F to 122 °F), 10% to 60% RH Low: 0 °C to 40 °C (32 °F to 104 °F) 10% to 90% RH |
Nonoperating | High: 40 °C to 60 °C (104 °F to 122 °F), 10% to 60% RH Low: 0 °C to 40 °C (32 °F to 104 °F) 5% to 90% RH |
Attitude | |
Operating | Up to 3,000 meters |
Nonoperating | Up to 12,000 meters |
Power Requirements
The TPA-N-PRE is powered directly from the RF input on MDO4000 and MDO3000 Series oscilloscopes.
Regulatory
Compliance labeling: WEEE (European Union).
Recommended Oscilloscopes
MDO4000 and MDO3000 Mixed Domain Oscilloscopes
Note:
For best probe support, download and install the latest version of the oscilloscope firmware from
Warranty information
One year parts and labor.
Ordering Information
TPA-N-PRE
MDO4000 and MDO3000 Pre-Amplifier. Includes Instruction Manual (English) (071-3058-XX)
Service Options
Opt. C3 –
Calibration Service 3 years (initial certification, plus 2 calibrations).
Opt. C5 –
Calibration Service 5 years (initial certification, plus 4 calibrations).
Opt. R3 –
Repair Service. Repair warranty extended to cover 3 years.
Opt. R5 –
Repair Service. Repair warranty extended to cover 3 years.
Additional Service Products Available During Warranty (DW)
TPA-N-PRE R3DW –
Repair Service Coverage 3 Years (includes product warranty period). 3-year period starts at time of customer instrument purchase
TPA-N-PRE R5DW –
Repair Service Coverage 5 Years (includes product warranty period). 5-year period starts at time of customer instrument purchase