<span style="font-family: 宋体; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">故障一:油泵启动后,低压断路开关跳闸
<span style="font-family: 宋体; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">此类故障需要以下检查:
1<span style="font-family: 宋体; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">、检查电源的缺相现象。
2<span style="font-family: 宋体; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">、检查高压滤芯是否严重阻塞,导致油泵电机电流太大。
3<span style="font-family: 宋体; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">、检查低压断路开关是否设定太小。
<span style="font-family: 宋体; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">故障二:开机后,回参考点时找不到参考点
1<span style="font-family: 宋体; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">、由于光栅尺的读数头连接部位是否松脱,导致机器在回程时,读数头不能与光栅尺的参考点重合而此时油缸的行程已用完,油泵处于工作负载状态。如是这一原因,则需要按下数控系统的红色停止键,停止回参考点,重新连接校正好光栅尺的连接板,再进入手动模式工作状态下,使滑块手动向下,让滑块与下模重合时再进入手动或半自动模式工作状态,重新回参考点,排除故障。
2<span style="font-family: 宋体; mso-ascii-font-family: "times new roman"; mso-hansi-font-family: "times new roman";">、机器在上次操作完毕后,由于操作人员未严格按照操作关机,将机器断电前把滑块停在上死点位置,而在下次开机时,未将滑块手动向下,放置上下模重合后的位置,而进行回参考点操作,引起该次操作不能找回参考点,如果是这一原因,则需要将系统转为手动状态,手动模式将滑块下行*、下模重合位置,再进入半自动或自动模式状态下,重新找回参考点。