美国Simpson辛普森交流/直流泄漏电流测试仪

228美国Simpson辛普森交流/直流泄漏电流测试仪

参考价: 面议

具体成交价以合同协议为准
2022-05-17 18:40:04
20
产品属性
关闭
深圳美科仪科技有限公司

深圳美科仪科技有限公司

初级会员1
收藏

组合推荐相似产品

产品简介

美国Simpson辛普森交流/直流泄漏电流测试仪Simpson-228,测试危险的交直流泄露电流,满足的UL, IEC, and ANSI相关规定,产地:美国,*。

详细介绍

美国Simpson辛普森交流/直流泄漏电流测试仪Simpson-228,测试危险的交直流泄露电流,满足的UL, IEC, and ANSI相关规定,产地:美国,*。

美国Simpson辛普森交流/直流泄漏电流测试仪Simpson-228特点:

Simpson-228模拟三个级别人体反应,每个完整仪器包括:测试引线,鳄鱼夹,手册,电池

检测电气或电子设备的导电表面上存在的危险交直流泄漏电流。

满足新的规范:IEC, ANSI, and UL

模拟三种人体接触级别:Reaction, Let-Go and Unweighted Burn Hazard

电池供电

Simpson-228测试参数:

Equivalent measuring instrument load

Reaction Response Network

1 MΩ - 10pF

Let-Go Response Network

1 MΩ - 62pF

Unweighted Burn Hazard Response Network

1 MΩ - 1pF

Ranges

Reaction Response Network

.3, 1, 3, 10 M.I.U.

Let-Go Response Network

.3, 1, 3, 10 M.I.U.

Unweighted Burn Hazard Response Network

0-100 mA RMS

Meter accuracy

±2% F.S. @ 60 Hz

Meter frequency response

DC to 1 Hz

Pointer shall track within 5% of peak

15 Hz to 200 KHz

±2% of F.S.

200 KHz to 1 MHz

±2% F.S., ±2% F.S., ±5%F.S.

Output

Sensitivity

Full scale meter indication equals 1Ω RMS (Measured with a 1 MV, 12 pF load)

Accuracy

±2% of reading @ 60 Hz

Output frequency response

Type

0.52" (13.2mm) Diameter Electret Condenser, Omnidirectional 70° angle of incidence. Maximum sound pressure level 148dB

Display

DC to 1Hz

±2% of reading

50 Hz to 100 KHz

±2.5% of reading, +2%/-3% of reading, ±2% of reading

100 kHz to 1 MHz

±5% of reading

Voltmeter

Range

0-300 V (AC or DC)

Accuracy: DC to 1 Hz

Pointer shall track within 5% of peak

Accuracy: 20 Hz to 1KHz

±3% F.S. @ 60 Hz

Frequency response

DC to 1 KHz

General

Power requirements

(2) 9V (NEDA 1604A) batteries

Physical

7" x 5.25" x 3", 2-1/2 lbs (1.4kg), ABS plastic, fused input

Environmental

27°C ±2°C, 70% noncondensing relative humidity. Outside this range derate by 10% per °C

Maximum operating range

0° to 40° C

 